SCV-5.2 Intelligent Vickers Hardness Tester

Short Description:


Product Detail

Product Tags

Overview

The SCV-5.2 XYZ Fully Automatic Intelligent Vickers Hardness Tester is a precision Vickers hardness testing instrument that replaces the imported upwarddownward moving measuring head structure. It is designed specifically to meet diverse material testing requirements.

Equipped with an electronic loading closedloop control system, it offers a wide test force range from 10 gf to 10 kgf (or optional 10 gf to 50 kgf), fully covering the common test forces used in industry. It can flexibly handle hardness testing challenges for various materials. With its outstanding performance and flexible configuration, it provides allround support and assurance for your material testing.

Product Features

Lifting measuring head structure with fixed worktable for enhanced stability during testing.

Zaxis electric focusing: Quickly and accurately locates the focal plane, improves testing efficiency, enhances automation, and reduces operational difficulty.

Equipped with an XY automatic worktable to realize fully automatic measurement and a series of testing applications, including sample profile scanning, automatic indentation, continuous indentation, automatic focusing, and multipoint continuous measurement.

Advanced optics and safety technology: A unique optical system ensures clear imaging, perfectly integrated with anticollision safety technology to guarantee operational safety.

Digital zoom and powerful testing system: Digital zoom provides a wide magnification range. Combined with longworkingdistance objectives and a highprecision automatic stage, it forms a robust testing system that ensures accurate results.

Highly integrated intelligence: All hardware and software are elaborately designed, assembled, and integrated as a whole, improving the intelligence of the hardness tester while ensuring stable and reliable test results.

Customizable testing space: Testing space and worktable can be customized according to different specimen sizes, flexibly adapting to various testing scenarios.

Image recognition system: Adopts a unique algorithm with strong recognition capability and high precision, ensuring accurate measurements and further improving testing efficiency and accuracy.

Application Range

Widely used for hardness testing of various materials including steel, non-ferrous metals, IC wafers, thin plastics, metal foils, plating layers, coatings, surface-hardened layers, laminated metals, hardened depth of heat-treated carburized layers, cemented carbides, ceramics, etc.

It is also suitable for hardness testing of thin sheets, electroplating, welded joints or deposited layers, providing strong support for materials science research and industrial quality control.

Technical Specifications

Hardness Testing Range: 5–3000 HV, covering the hardness testing range of various materials.

Test Force: Ranges from 10 gf to 10 kgf (optional 100 gf to 50 kgf), suitable for testing requirements of different materials.

Optional Test Forces (1):0.01 kgf, 0.25 kgf, 0.05 kgf, 0.1 kgf, 0.2 kgf, 0.3 kgf, 0.5 kgf, 1 kgf, 2 kgf, 2.5 kgf, 3 kgf, 5 kgf, 10 kgf(0.098 N, 0.246 N, 0.49 N, 0.98 N, 1.96 N, 2.94 N, 4.90 N, 9.80 N, 19.6 N, 24.5 N, 29.4 N, 49 N, 98 N)

Optional Test Forces (2):0.01 kgf, 0.25 kgf, 0.05 kgf, 0.1 kgf, 0.2 kgf, 0.3 kgf, 0.5 kgf, 1 kgf, 2 kgf, 2.5 kgf, 3 kgf, 5 kgf, 10 kgf, 20 kgf, 30 kgf, 50 kgf(0.98 N, 1.96 N, 2.94 N, 4.90 N, 9.80 N, 19.6 N, 24.5 N, 29.4 N, 49 N, 98 N, 196 N, 294 N, 490 N)

Standards Compliance: Conforms to GB/T 4340, ISO 6507, ASTM E384 and other international and domestic standards.

XY Automatic Stage: 50 mm × 50 mm.Positioning repeatability: < 2 μm;XYZ positioning resolution: up to 2 μm, ensuring precise positioning during testing.

Resolution: 0.1 μm, meeting highprecision testing requirements.

Test Force Application: Automatic loading, dwell, and unloading, simple and efficient operation.

Indenter & Objective Switching: Automatic switching supported, improving testing efficiency and reducing human error.

Objective Magnification: Highdefinition objectives: 10× and 50× (optional 10× & 20×) for detailed observation.

Stations: Standard 3 stations (supports up to 6 stations to meet various testing needs).

Conversion Scales: Supports conversion among HR, HB, HV and other hardness units for convenient comparison and analysis.

Test Force Dwell Time: Adjustable from 1–99 s to meet requirements under different testing conditions.

Measuring Head Travel: 170 mm (customizable), suitable for specimens of different sizes.

Distance from Indenter Center to Machine Body: 135 mm (customizable), ensuring stable and reliable testing.

Vickers Indentation Measurement System: Highprecision measurement, ensuring accurate test results.

Power Supply: AC 220 V / 50 Hz

Weight: 70 kg

Standard configuration includes high-definition 10× and 50× objectives, with multiple objectives and indenters available as options.

XY fully automatic workbench

Test Sample Interface

Test Method Interface

Test Results Interface

Test Results Interface (Multipoint Thumbnails)

Statistical Chart Interface

History Record Interface

Standard Configuration

Main Unit: 1 pc               Standard Test Blocks: 2 pcs

10× Objective: 1 pc        50× Objective: 1 pc

Automatic Stage: 1 pc    Computer System: 1 set

Small Level: 1 pc            Vickers Indenter: 1 pc

Power Cord: 1 pc

 

 